PD10-48-1515 |
Total power : 10 Watts
Input voltages : 5V, 12V, 24, 48V Input
#of outputs : Single,Dual output
![]() |
SPECIAL FEATURES |
- High efficiency
- 300KHz fixed frequency
- Wide 2:1 input range
- Isolated Output
- Surface mounting technology
- small,compact size 1.85"×1.65"×0.35"
- Current mode control
- Output low ripple and noise
- Low start up current
- 3 Years warranty
![]() |
ENVIRONMENTAL |
- Operating temperature range..........-20°C ~ 71°C
- Option, See Note1....................-40°C ~ 85°C
- Storage temperature range..........-40°C ~ 105°C
- Operating humidity(non condensing)..........20% ~ 90%RH
- Storage humidity(non condensing)..........10% ~ 95%RH
- Cooling method..........Convection
- Case material .........Zn
- MTBF..........4.8×105hrs
![]() |
ELECTRICAL SPECIFICATIONS |
INPUT
- Input range ....................................... DC 4.5V - 7.2V, 8V - 16.5V, 18V -32V, 32V - 63V
- Efficiency ......................................... 72 - 85% typ.
OUTPUT
- Voltage tolerance .............................. ±2% (Single and uncomplementary daul) ±3% (Complementary dual)
- Line regulation .................................. ±0.5%
- Load regulation ................................. ±1% @ single ±2.5% @ dual (minimum load 10%) ±1% output1,±4% output2 @dual
- Ripple and Noise, pk-pk ..................... Bandwidth : 20MHz Magnitude : 1% Vout nom
PROTECTION CIRCUIT
- Short circuit protection ........................ Current limited output (note2)
ELECTRICALLY ISOLATED
- Isolation ............................................ Input-output, input-case, output-case / DC 500V, 100Mohms
- High pot ............................................ Input-output, input-case, output-case / AC 500V, 1minute
NOTE 1. As a factory added option, the all model can be operated down to -40℃, the suffix 'M' should be added to the model number when ordering. NOTE 2. Long term continuous operation into a short circuit will compromise the reliability of the unit.
NOTE
1. As a factory added option,the all model can be operated down to operated down to operated down to -40°C, the suffix(M)should be added to the mo-del number when ordering e.x PS10-24-5M
2. Long term continuous operation into a short circuit will compromi-se the reliability of the unit