SFS5-24 |
Total Power : 5, 10 Watts
Input Voltages : AC85~264V or DC110~340V
#of outputs : Single
![]() |
DIMENSIONS |

![]() |
SPECIAL FEATURES |
- Encapsulated, compactcase
- High efficiency
- Surface mounting techonlogy
- 100KHz fixed frequency
- Fixed output voltage
- Thermal shutdown
- Output short circuit protection
- Low output ripple & noise
- Isolated output (3KVAC)
- Over vlotage protection (O.V.P.)
- Overcurrent protection (O.C.P.)
- Low no-load power cosumption
- 5Years warranty Environmental
![]() |
ENVIRONMENTAL |
- Operation temperature range ....... -20℃~70℃
- Storage temperature range ......... -40℃~80℃
- Humidity .......................... 20%~90%RH
- Vibration ........ 10~55Hz at 10G 3minutes period
- Impact ....... 50G for 11ms, once on dach X, Y and Z-axis
- Cooling method..................... convection
- Case Material ......................... PBT
- MTBF(MIL-HDBK-217F) .............. 4.5×105hrs
- Safety *Approved ...........UL(UL60950, CSA C22.2 NO.60950) : E227474 / CB(IEC 60950) / CE (EN 60950)
- through TUV
- EMC meet CISPR 22-B
![]() |
ELECTRICAL SPECIFICATIONS |
INPUT
- Voltage ................................... AC85~264V (or DC 110~340) 50/60Hz (note)
- Current .................................... 0.15A max. @ 110VAC / 0.08A max. @ 220VAC
- Frequency ............................... 47~440Hz max. (50~60Hz typ.)
- Efficiency ................................. 75% typ.
- Inrush current ........................... 20A max. @ 110VAC / 40A max. @ 220VAC
- Leakage current ....................... 0.5mA max. @ 110VAC / 0.75mA max. @ 220VAC
OUTPUT
- Voltage tolerance ..................... ±2% (single and uncomplementary dual)
- Ripple and noise ..................... ±1% typ.
- Line regulation ........................ ±1% typ.
- Load regulation ....................... ±1% typ.
- Dynamic load regulation .......... ±3% typ.
- Temperature drift .................... ±1% typ.
- Rising time ............................ 100ms max.
- Holding time .......................... 10ms min.
PROTECTION CIRCUIT
- Over voltage protection ........... clamp, 130~150%
- Over current protection ........... Work at over 105% of rating & recovers automatically
- Over temperature protection .... 150℃ Latching, Recovery
ELECTRICALLY ISOLATED
- Input-Output .......................... AC 3KV, 1minute, 10mA / DC 500V, 100Mohms min.
NOTE
- For cases where conformance to various safety specs (UL, CSA, CE, CB etc) are reguired input voltage and frequency range will be 100-240 VAC, 50~60Hz.